Hydraulic breaker does not impact or impact intermittent treatment

Release time:2022/04/01 Click volume:0
Hydraulic breaker does not impact or impact intermittent treatment

  Since the hydraulic breaker hammer reciprocates to work, the output impact energy can be operated. The harsh working conditions make the hydraulic impactor often fail, which seriously affects the construction progress. Professionals have introduced us to the faults frequently encountered in the use of hydraulic breakers, analyzed the causes of the faults, and proposed troubleshooting. Methods. Common faults of hydraulic breakers include impactor without impact, impactor impact but reduced impact force, piston movement but no impact, low impact frequency, low force, broken hammer piston, etc. The continuation is the most common situation. This article analyzes this in detail and proposes a complete set of solutions, hoping to inspire you. There are usually 3 cases without impact or impact. See below for specific details.
  In the first case, there is not enough high-pressure oil flowing into the interior of the impactor without impact. The main reason for the analysis is that the pipeline is clogged or damaged or there is not enough hydraulic oil;
  The treatment measures are:
  (1) Check and repair the hose or replace it;
  (2) Check the fuel supply system.
  The second is that there is enough high-pressure oil, but the impactor does not impact, the main reason is
  (1) The returning oil pipe is connected incorrectly;
  (2) The working pressure is lower than the specified value;
  (3) The piston is stuck;
  (4) The reversing spool is stuck;
  (5) the shutoff valve is not open;
  (6) The nitrogen pressure in the accumulator or nitrogen chamber is too high;
  (7) The oil temperature is higher than 80 degrees.
  The main exclusion measures are
  (1) correcting;
  (2) Adjust the system pressure;
  (3) Whether the piston is moved by hand or not, if the piston cannot move flexibly, the piston and the guide sleeve have been scratched, and the guide sleeve should be replaced. If possible, the piston should also be replaced;
  (4) Remove the valve core for cleaning and repair;
  (5) opening the shutoff valve;
  (6) mediating the nitrogen pressure of the accumulator or nitrogen chamber;
  (7) Check the cooling system and lower the oil temperature to the working temperature.
  The third is the piston movement but does not impact. This situation is relatively easy, the main reason is that the drill rod is stuck, the drill rod can be removed and repaired with a grinding wheel or oil stone.